| [EPCOS POWER FACTOR CORRECTION] |
|
 |
PHASECAP ® AC CAPACITORS - [TECHNICAL DATA] |
|
|
|
|
Standards IEC 831-1/96, IEC 831-2/95, EN 60831-1 +2/96, VDE 560-46+47 3/95. |
|
|
| |
|
|
|
| |
|
|
|
|
|
| |
U max. |
Un + 10 % (Up to 8 h daily) /Un + 15 % (Up to 30 |
| |
|
min daily) / Un + 20 % (up to 5 min) / Un + 30% |
| |
|
(Up to 1 min 200 times during useful life.) |
|
|
|
| Frequency |
I max. |
1.3 * In, in certain cases higher [See Table] |
|
|
|
| Losses (dieelectric) |
Is |
100 * In |
|
|
|
| Capacitance |
|
50 / 60 Hz |
|
|
|
| Test voltage, terminal / |
|
0.5 W kvar |
|
|
|
| Test voltage, terminal / case |
UTT |
-5 % / +10 s |
|
|
|
| Useful life |
UTC |
100,000 h |
|
|
|
| Ambient Temperature |
Tld (co) |
-25%D, max. 55° C |
|
|
|
| Cooling |
LCT/ |
natural or forced |
| Humidity |
UCT |
max.95 % |
|
|
|
| Altitude |
|
2000 m asl (Above sea level) |
|
|
|
| Cooling |
|
random except upside down. |
|
|
|
| Humidity |
Hrel |
threaded M12 stud (10 Nm) for case dia > 53 mm, |
| |
|
M8 (4 Nm) for case dia > 53 mm |
|
|
|
| Safety |
|
overpressure disconnector, self-healing |
|
|
|
| Discharge resistors |
|
discharge module included. |
|
|
|
| Case |
|
extruded aluminium. |
|
|
|
| Enclosure |
|
IP20, indoor mounting (optional IP32) |
|
|
|
| Dieelectric |
|
polypropylene film. |
|
|
|
| Impregnation |
|
non=PCB, Vegetable oil based resin. |
|
|
|
| Terminals |
|
Screw terminals for B32344, fast-on terminal for |
| |
|
B32340 and B32343. |
|
|
|
| Certification |
|
UL for B32340 up to 450 Vac, UL pending for other |
| |
|
series. |
|
|
|
| |
|
|
|
|
|
|
|
| |
 |
PHASECAP ® AC CAPACITORS - [ HIGH INRUSH CURRENT WITHSTAND CAPABILITY IS CRUCIAL ] |
|
|
|
| |
Capacitors used for power factor correction undergo a lot of switching operations. The high |
| |
inrush currents that to along with this must be handled without degrading useful life. The pulse |
| |
strength of this technology comes in particular from the enlarged contact area ( heavy edge |
| |
metalization) and metal sprayed contact (face side winding element) |
| |
|
|
|
|
|
|
 |
PHASECAP ® AC CAPACITORS - [ AND WHERE IT IS CRUCIAL] |
|
|
|
| |
Parallel connection of capacitors. |
| |
Non-detuned capacitors. |
| |
Capacitor bank using standard contactors. |
| |
|
| |
|
|
|
|
|
|
 |
PHASECAP ® AC CAPACITORS - [ USEFUL LIFE UP TO 100,000 OPERATING HOURS ] |
|
|
|
| |
After a long drying phase in high vacuum to eliminate moisture from the active element, the |
| |
capacitor is filled with biodegradeable soft resin. This production helps to avoid oxidation and |
| |
partial discharges, promoting capacitance stability over a long period. |
|
|
| |
Phicap is a self-healing, metalized polypropylene film capacitor. The current carrying AIZ |
| |
mental layer (the best alloy for an electrode) is vapor-deposited once one side of the film, the |
| |
surface of the dieelectric. |
| |
|
| |
|
|
|
|
|
|
 |
PHASECAP ® AC CAPACITORS - [ COMPACT DESIGN - LOW WEIGHT AND VOLUME ] |
|
|
|
| |
The entire three-phase capacitor is composed of three single-phase element stacks. The |
| |
electrodes are connected by metal spraying the face endsof the windingelements.The winding |
| |
elements are encapsulated in a cylindrical aluminum case and hermetically sealed by a press |
| |
rolled metal lid or plastic disk with fast-on terminals. |
| |
|
| |
|
|
|
|
|
|
 |
PHICAP ® AC CAPACITORS - [ DUAL SAFETY SYSTEMS] |
|
|
|
| |
Self-healing: the capacitor repairs itself after overload. Self-healing capability prevents |
| |
permanent dielectric breakdown in the event of sporadic voltage surges, over current or over |
| |
temperature. |
|
|
| |
Overpressure disconnector: this prevents the capacitor from bursting at the end of its useful |
| |
life or through electricalor thermal overload. In the event of permanent self-healing attempts |
| |
caused by repetitive, very highpeak voltages or other overload, there can be permanent |
| |
breakdown. The safety switching device is then activated and disconnects the capacitor |
| |
winding elements from the power source by an internal pressure increase (expansion of the |
| |
capacitor case). |
| |
|
| |
|
|
|
|
|
|
 |
PHICAP ® AC CAPACITORS - [ DESIGN TIPS ] |
|
|
|
| |
Becauseof the increase in capacitor height on breakdown, it is necessary to provide enough |
| |
clearance above the capacitor terminals. |
| |
|
| |
|
|
|
|
|
|
 |
PHASECAP ® AC CAPACITORS - [CONNECTION TECHNOLOGY] |
|
|
|
| |
Simplified parallel connection of capacitors (double fast-on-terminal or double wire clamping |
| |
screw terminals) |
| |
Discharge resistor already mounted; standard for extra reliability and safety. |
| |
Cable Connection layout (terminals) for secure, safe clamping of required cable cross-section. |
| |
|
| |
|
|
|
|
|
|
 |
PHASECAP ® AC CAPACITORS - [OVERPRESSURE DISCONNECTOR] |
|
|
|
| |
 |
|
 |
PHASECAP ® AC CAPACITORS - [ PHI CAP SELECTION ] |
|
|
|
| |
When specifying and selecting capacitors for PEC, there are several factors affecting |
| |
performance and useful life. |
| |
Voltage, |
| |
Harmonics, |
| |
Temperature, |
| |
Inrush current. |
|
|
| |
Permanent overvoltage shortens the useful life of a capacitor. The capacitors nominal voltage |
| |
must be equal to or greater than the operating voltage of the circuit the capacitor will be |
| |
connected to. |
|
|
| |
Harmoncis produce overvoltage and overcurrent on capacitors. If the total harmoinc distortion |
| |
level for voltage exceeds 5% for example, serious damage can be caused by circuit resonace. |
| |
In such cases series reactors (detuning) and recommended. |
|
|
| |
Operation of capacitors above the upper catagory temperature will accelerate degradation of |
| |
the dielectric and shorten the capacitor's useful life. |
|
|
| |
Residual voltage should not exceed 10% of rated voltage when reswitching capacitors. During |
| |
the charging period of capacitors the current is very high - in automatic capacitor bank it is |
| |
very like that discharged capacitors will be connected to charged ones already connected to |
| |
the grid. In such cases the maximum admissible transient peak current is 100 * IN. |
|
|
| |
During the switching process, thermal and electrodynamics stress is produced by transient |
| |
overcurrents of high amplitude and frequency and may damage the system. Capacitor |
| |
contactors with precharging resistors or series inductance (twinned cables between contactor |
| |
and capacitor) will avoid excessive transient currents. |
| |
|
|
|
|
|
|
| * LP- List Price inclusive of excise duty but exclusive of sales tax or any other taxes. |
|
|
|
|
|
| |
For Improved power quality and reduction in energy costs. |