| Auxiliary Supply |
: |
110V model (Range 85-130V) |
| |
|
240V model (Range 180-270V) |
| Burden |
: |
0.2 VA max. Per input for voltage & current signals |
| |
|
3 VA max. on auxiliary supply |
| Accuracy |
: |
Class 1.0 for Volt/Ammeter/KWh/PF Meter (Class 0.5 on |
| |
|
request) for
Hz 0.1% of full scale |
| Display |
: |
0.5 inches, 7 Segment super bright LED s/ |
| |
|
4 digit, 0.35 inches, 7 Segment for Hz Meter in 3 phase |
| |
|
combined meter/ |
| |
|
6 digit, 0.35 inches, 7 segment display for Digital Led KWh |
| |
|
meter/ |
| |
|
6 digit tamper proof non- resetable mechanical counter |
| |
|
for KWh meter. |
| Computation |
: |
True RMS for all Power & Energy Parameters. |
| Frequency Range |
: |
45 – 55Hz |
| Power Factor |
: |
0.5 Lag – 1-0.8 Lead |
| Resolution |
: |
1 count for Voltmeter / KW Meter |
| |
|
0.01 for frequency Meter & PF Meter |
| |
|
0.1 for CT ratio < 100 A |
| |
|
1 count for CT ratio > 100A – 1000A |
| |
|
0.01 kA for CT ratio > 100A |
| Inputs |
: |
Volts – 0-500V AC |
| |
|
Amps – 0.25 – 6.0A for 5A model |
| |
|
0.05 – 1.2 Amps for 1A model |
| |
|
Freq. 30-500V AC |
| Burdune of isolated |
: |
24 DC, 100mA max. |
| Output for KWh Meter pulse width |
|
|
| of isolated output |
: |
Approx. 500m sec. |
| Ambient |
: |
0-50 0 C |
| Humidity |
: |
< 95% non-condensing |
| Weight |
: |
Approx – 500 gms. |
| Dimension |
: |
96 x 96 x 80 mm |
| Panel Cutout |
: |
(90 + -0)mm x (90 + -0)mm |
| Mounting |
: |
Flush mounting with side clamps. |